Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 220
Filtrar
1.
bioRxiv ; 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38712109

RESUMEN

Background: The understanding of how varying radiation beam parameter settings affect the induction and magnitude of the FLASH effect remains limited. Purpose: We sought to evaluate how the magnitude of radiation-induced gastrointestinal (GI) toxicity (RIGIT) depends on the interplay between mean dose rate (MDR) and dose per pulse (DPP). Methods: C57BL/6J mice were subjected to total abdominal irradiation (11-14 Gy single fraction) under conventional irradiation (low DPP and low MDR, CONV) and various combinations of DPP and MDR up to ultra-high-dose-rate (UHDR) beam conditions. The effects of DPP were evaluated for DPPs of 1-6 Gy while the total dose and MDR were kept constant; the effects of MDR were evaluated for the range 0.3- 1440 Gy/s while the total dose and DPP were kept constant. RIGIT was quantified in non-tumor-bearing mice through the regenerating crypt assay and survival assessment. Tumor response was evaluated through tumor growth delay. Results: Within each tested total dose using a constant MDR (>100 Gy/s), increasing DPP led to better sparing of regenerating crypts, with a more prominent effect seen at 12 and 14 Gy TAI. However, at fixed DPPs >4 Gy, similar sparing of crypts was demonstrated irrespective of MDR (from 0.3 to 1440 Gy/s). At a fixed high DPP of 4.7 Gy, survival was equivalently improved relative to CONV for all MDRs from 0.3 Gy/s to 104 Gy/s, but at a lower DPP of 0.93 Gy, increasing MDR produced a greater survival effect. We also confirmed that high DPP, regardless of MDR, produced the same magnitude of tumor growth delay relative to CONV using a clinically relevant melanoma mouse model. Conclusions: This study demonstrates the strong influence that the beam parameter settings have on the magnitude of the FLASH effect. Both high DPP and UHDR appeared independently sufficient to produce FLASH sparing of GI toxicity, while isoeffective tumor response was maintained across all conditions.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38615887

RESUMEN

PURPOSE: Only a subset of patients with severe emphysema qualify for lung volume reduction surgery or endobronchial valves. We previously demonstrated that stereotactic ablative radiation therapy of lung tumors reduces lung volume in treated lobes by creating localized lung fibrosis. We aimed to determine the safety and secondarily explore the efficacy of stereotactic irradiation for lung volume reduction (SILVR) over 18 months after intervention in patients with severe emphysema. METHODS AND MATERIALS: We conducted a single-arm, prospective clinical trial in eligible patients with severe emphysema treated with unilateral stereotactic ablative radiation therapy (45 Gy in 3 fractions) to a target within the most emphysematous region. The primary outcome was safety in terms of incidence of grade ≥3 adverse events, and the secondary outcome was efficacy. RESULTS: Eight patients received the intervention. Median (range) baseline characteristics were age 73 years (63-78); forced expiratory volume in 1 second percent of predicted value (FEV1%) 28.5% (19.0-42.0); diffusing capacity of the lungs for carbon monoxide percent of predicted value 40% (24.0-67.0); and body mass index, airflow obstruction, dyspnea, and exercise capacity (BODE) index 5.5 (5-9). The incidence of grade ≥3 adverse events was 3 of 8 (37.5%). The relative change in target lobe volume was -23.1% (-1.6 to -41.5) and -26.5% (-20.6 to -40.8) at 6 and 18 months, respectively. The absolute ΔFEV1% was greater in patients with a BODE index ≤5 versus ≥6 (+12.0% vs -2.0%). The mean baseline lung density (in Hounsfield units, reflecting the amount of preserved parenchyma) within the intermediate dose volume (V60BED3) correlated with the absolute change in target lobe volume at 18 months. CONCLUSIONS: SILVR appears to be safe, with a signal for efficacy as a novel therapeutic alternative for patients with severe emphysema. SILVR may be most safe and effective in patients with a lower BODE index and/or less parenchymal destruction.

3.
Radiother Oncol ; 196: 110317, 2024 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-38679202

RESUMEN

BACKGROUND AND PURPOSE: Concerns over chest wall toxicity has led to debates on treating tumors adjacent to the chest wall with single-fraction stereotactic ablative radiotherapy (SABR). We performed a secondary analysis of patients treated on the prospective iSABR trial to determine the incidence and grade of chest wall pain and modeled dose-response to guide radiation planning and estimate risk. MATERIALS AND METHODS: This analysis included 99 tumors in 92 patients that were treated with 25 Gy in one fraction on the iSABR trial which individualized dose by tumor size and location. Toxicity events were prospectively collected and graded based on the CTCAE version 4. Dose-response modeling was performed using a logistic model with maximum likelihood method utilized for parameter fitting. RESULTS: There were 22 grade 1 or higher chest wall pain events, including five grade 2 events and zero grade 3 or higher events. The volume receiving at least 11 Gy (V11Gy) and the minimum dose to the hottest 2 cc (D2cc) were most highly correlated with toxicity. When dichotomized by an estimated incidence of ≥ 20 % toxicity, the D2cc > 17 Gy (36.6 % vs. 3.7 %, p < 0.01) and V11Gy > 28 cc (40.0 % vs. 8.1 %, p < 0.01) constraints were predictive of chest wall pain, including among a subset of patients with tumors abutting or adjacent to the chest wall. CONCLUSION: For small, peripheral tumors, single-fraction SABR is associated with modest rates of low-grade chest wall pain. Proximity to the chest wall may not contraindicate single fractionation when using highly conformal, image-guided techniques with sharp dose gradients.

4.
J Natl Compr Canc Netw ; 22(2): 72-81, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38503043

RESUMEN

Mesothelioma is a rare cancer that originates from the mesothelial surfaces of the pleura and other sites, and is estimated to occur in approximately 3,500 people in the United States annually. Pleural mesothelioma is the most common type and represents approximately 85% of these cases. The NCCN Guidelines for Mesothelioma: Pleural provide recommendations for the diagnosis, evaluation, treatment, and follow-up for patients with pleural mesothelioma. These NCCN Guidelines Insights highlight significant updates to the NCCN Guidelines for Mesothelioma: Pleural, including revised guidance on disease classification and systemic therapy options.


Asunto(s)
Mesotelioma Maligno , Mesotelioma , Neoplasias Pleurales , Humanos , Pleura , Mesotelioma/diagnóstico , Mesotelioma/terapia , Neoplasias Pleurales/diagnóstico , Neoplasias Pleurales/terapia
5.
Artículo en Inglés | MEDLINE | ID: mdl-38493902

RESUMEN

PURPOSE: We conducted a multi-institutional dosimetric audit between FLASH and conventional dose rate (CONV) electron irradiations by using an anatomically realistic 3-dimensional (3D) printed mouse phantom. METHODS AND MATERIALS: A computed tomography (CT) scan of a live mouse was used to create a 3D model of bony anatomy, lungs, and soft tissue. A dual-nozzle 3D printer was used to print the mouse phantom using acrylonitrile butadiene styrene (∼1.02 g/cm3) and polylactic acid (∼1.24 g/cm3) simultaneously to simulate soft tissue and bone densities, respectively. The lungs were printed separately using lightweight polylactic acid (∼0.64 g/cm3). Hounsfield units (HU), densities, and print-to-print stability of the phantoms were assessed. Three institutions were each provided a phantom and each institution performed 2 replicates of irradiations at selected anatomic regions. The average dose difference between FLASH and CONV dose distributions and deviation from the prescribed dose were measured with radiochromic film. RESULTS: Compared with the reference CT scan, CT scans of the phantom demonstrated mass density differences of 0.10 g/cm3 for bone, 0.12 g/cm3 for lung, and 0.03 g/cm3 for soft tissue regions. Differences in HU between phantoms were <10 HU for soft tissue and bone, with lung showing the most variation (54 HU), but with minimal effect on dose distribution (<0.5%). Mean differences between FLASH and CONV decreased from the first to the second replicate (4.3%-1.2%), and differences from the prescribed dose decreased for both CONV (3.6%-2.5%) and FLASH (6.4%-2.7%). Total dose accuracy suggests consistent pulse dose and pulse number, although these were not specifically assessed. Positioning variability was observed, likely due to the absence of robust positioning aids or image guidance. CONCLUSIONS: This study marks the first dosimetric audit for FLASH using a nonhomogeneous phantom, challenging conventional calibration practices reliant on homogeneous phantoms. The comparison protocol offers a framework for credentialing multi-institutional studies in FLASH preclinical research to enhance reproducibility of biologic findings.

6.
Artículo en Inglés | MEDLINE | ID: mdl-38171387

RESUMEN

PURPOSE: Ultrahigh-dose-rate (FLASH) irradiation has been reported to reduce normal tissue damage compared with conventional dose rate (CONV) irradiation without compromising tumor control. This proof-of-concept study aims to develop a deep learning (DL) approach to quantify the FLASH isoeffective dose (dose of CONV that would be required to produce the same effect as the given physical FLASH dose) with postirradiation mouse intestinal histology images. METHODS AND MATERIALS: Eighty-four healthy C57BL/6J female mice underwent 16 MeV electron CONV (0.12 Gy/s; n = 41) or FLASH (200 Gy/s; n = 43) single fraction whole abdominal irradiation. Physical dose ranged from 12 to 16 Gy for FLASH and 11 to 15 Gy for CONV in 1 Gy increments. Four days after irradiation, 9 jejunum cross-sections from each mouse were hematoxylin and eosin stained and digitized for histological analysis. CONV data set was randomly split into training (n = 33) and testing (n = 8) data sets. ResNet101-based DL models were retrained using the CONV training data set to estimate the dose based on histological features. The classical manual crypt counting (CC) approach was implemented for model comparison. Cross-section-wise mean squared error was computed to evaluate the dose estimation accuracy of both approaches. The validated DL model was applied to the FLASH data set to map the physical FLASH dose into the isoeffective dose. RESULTS: The DL model achieved a cross-section-wise mean squared error of 0.20 Gy2 on the CONV testing data set compared with 0.40 Gy2 of the CC approach. Isoeffective doses estimated by the DL model for FLASH doses of 12, 13, 14, 15, and 16 Gy were 12.19 ± 0.46, 12.54 ± 0.37, 12.69 ± 0.26, 12.84 ± 0.26, and 13.03 ± 0.28 Gy, respectively. CONCLUSIONS: Our proposed DL model achieved accurate CONV dose estimation. The DL model results indicate that in the physical dose range of 13 to 16 Gy, the biologic dose response of small intestinal tissue to FLASH irradiation is represented by a lower isoeffective dose compared with the physical dose. Our DL approach can be a tool for studying isoeffective doses of other radiation dose modifying interventions.

7.
Radiother Oncol ; 191: 110079, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38163486

RESUMEN

This prospective feasibility trial investigated pulmonary interstitial lymphography to identify thoracic primary nodal drainage (PND). A post-hoc analysis of nodal recurrences was compared with PND for patients with early-stage lung cancer; larger studies are needed to establish correlation. Exploratory PND-inclusive stereotactic ablative radiotherapy plans were assessed for dosimetric feasibility.


Asunto(s)
Neoplasias Pulmonares , Radiocirugia , Humanos , Pulmón , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirugía , Linfografía , Estudios Prospectivos , Estudios de Factibilidad
8.
Clin Lung Cancer ; 25(2): 186-189, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38040540

RESUMEN

INTRODUCTION: Prior attempts to escalate radiation dose for non-small cell lung cancer (NSCLC) have not improved survival. Given the high risk for cardiopulmonary toxicity with treatment and heterogenous presentation of locally advanced NSCLC, it is unlikely that a single dose regimen is optimal for all patients. This phase I/II trial aims to evaluate a novel treatment approach where the level of accelerated hypofractionation is determined by the predicted toxicity from dose to organs at risk (OARs). METHODS: Patients ≥ 18 years old with lung cancer planned for fractionated radiotherapy to the lung with concurrent chemotherapy will be eligible. Radiation therapy (RT) will be delivered to a total dose of 60 to 66 Gy in 30, 25, or 20 fractions depending on the ability to meet constraints to key organs at risk including the lungs, heart, and esophagus. The primary endpoint is high grade pulmonary, esophageal, or cardiac toxicity. A Bayesian optimized design is used to determine stopping boundaries and evaluate the primary endpoint. CONCLUSION: PACER will evaluate the safety and feasibility of personalized accelerated chemoradiotherapy for lung cancer.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Adolescente , Neoplasias Pulmonares/tratamiento farmacológico , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Teorema de Bayes , Quimioradioterapia/métodos , Pulmón , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Ensayos Clínicos Fase II como Asunto , Ensayos Clínicos Fase I como Asunto
9.
Clin Lung Cancer ; 25(2): e92-e100.e4, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38065707

RESUMEN

PURPOSE/OBJECTIVES: Adoption of hypofractionated accelerated radiation therapy (HART) with concurrent chemotherapy has been limited by toxicity concerns. We aimed to describe outcomes of patients treated with HART and concurrent chemotherapy and to evaluate dosimetry to organs at risk to guide patient selection. MATERIALS/METHODS: We evaluated a retrospective cohort of NSCLC patients treated with concurrent chemotherapy with HART (>2.2 Gy per fraction) or standard fractionated radiation therapy (SFRT; 2-2.2 Gy fractions). Dosimetric parameters to key organs at risk were compared, and toxicity, patterns of recurrence and survival were calculated for the cohorts. RESULTS: Fifty-three patients treated with HART were compared with 100 patients treated with SFRT. Median dose per fraction for the HART cohort was 2.75 Gy (range 2.4-3 Gy). HART patients had significantly lower doses to the lung, heart, and esophagus due to patient selection. The HART group and had rates of grade 2+ pneumonitis (9.4 vs. 19%, P = .16) and grade 2+ esophagitis (20.8 vs. 45%, P < .01) that compared favorably to SFRT. Cumulative incidence of in-field recurrence trended lower in the HART cohort (7.6% vs. 23.1%, P = .058). Among the HART group, 88.7% (47/53) met the newly proposed lung constraints based on the degree of hypofractionation CONCLUSION: In select patients with favorable dosimetry to organs at risk, definitive HART with concurrent chemotherapy achieved excellent local control with low toxicity. These results are being used to inform a prospective study on the safety and efficacy of HART with concurrent chemotherapy for select NSCLC patients.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Neoplasias Pulmonares/tratamiento farmacológico , Neoplasias Pulmonares/radioterapia , Hipofraccionamiento de la Dosis de Radiación , Estudios Retrospectivos , Estudios Prospectivos , Selección de Paciente
10.
Integr Biol (Camb) ; 152023 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-37874173

RESUMEN

Radiation therapy, one of the most effective therapies to treat cancer, is highly toxic to healthy tissue. The delivery of radiation at ultra-high dose rates, FLASH radiation therapy (FLASH), has been shown to maintain therapeutic anti-tumor efficacy while sparing normal tissues compared to conventional dose rate irradiation (CONV). Though promising, these studies have been limited mainly to murine models. Here, we leveraged enteroids, three-dimensional cell clusters that mimic the intestine, to study human-specific tissue response to radiation. We observed enteroids have a greater colony growth potential following FLASH compared with CONV. In addition, the enteroids that reformed following FLASH more frequently exhibited proper intestinal polarity. While we did not observe differences in enteroid damage across groups, we did see distinct transcriptomic changes. Specifically, the FLASH enteroids upregulated the expression of genes associated with the WNT-family, cell-cell adhesion, and hypoxia response. These studies validate human enteroids as a model to investigate FLASH and provide further evidence supporting clinical study of this therapy. Insight Box Promising work has been done to demonstrate the potential of ultra-high dose rate radiation (FLASH) to ablate cancerous tissue, while preserving healthy tissue. While encouraging, these findings have been primarily observed using pre-clinical murine and traditional two-dimensional cell culture. This study validates the use of human enteroids as a tool to investigate human-specific tissue response to FLASH. Specifically, the work described demonstrates the ability of enteroids to recapitulate previous in vivo findings, while also providing a lens through which to probe cellular and molecular-level responses to FLASH. The human enteroids described herein offer a powerful model that can be used to probe the underlying mechanisms of FLASH in future studies.


Asunto(s)
Técnicas de Cultivo de Célula , Intestinos , Humanos , Ratones , Animales
11.
Radiother Oncol ; 188: 109906, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37690668

RESUMEN

BACKGROUND AND PURPOSE: The impact of radiotherapy (RT) at ultra high vs conventional dose rate (FLASH vs CONV) on the generation and repair of DNA double strand breaks (DSBs) is an important question that remains to be investigated. Here, we tested the hypothesis as to whether FLASH-RT generates decreased chromosomal translocations compared to CONV-RT. MATERIALS AND METHODS: We used two FLASH validated electron beams and high-throughput rejoin and genome-wide translocation sequencing (HTGTS-JoinT-seq), employing S. aureus and S. pyogenes Cas9 "bait" DNA double strand breaks (DSBs) in HEK239T cells, to measure differences in bait-proximal repair and their genome-wide translocations to "prey" DSBs generated after various irradiation doses, dose rates and oxygen tensions (normoxic, 21% O2; physiological, 4% O2; hypoxic, 2% and 0.5% O2). Electron irradiation was delivered using a FLASH capable Varian Trilogy and the eRT6/Oriatron at CONV (0.08-0.13 Gy/s) and FLASH (1x102-5x106 Gy/s) dose rates. Related experiments using clonogenic survival and γH2AX foci in the 293T and the U87 glioblastoma lines were also performed to discern FLASH-RT vs CONV-RT DSB effects. RESULTS: Normoxic and physioxic irradiation of HEK293T cells increased translocations at the cost of decreasing bait-proximal repair but were indistinguishable between CONV-RT and FLASH-RT. Although no apparent increase in chromosome translocations was observed with hypoxia-induced apoptosis, the combined decrease in oxygen tension with IR dose-rate modulation did not reveal significant differences in the level of translocations nor in their junction structures. Furthermore, RT dose rate modality on U87 cells did not change γH2AX foci numbers at 1- and 24-hours post-irradiation nor did this affect 293T clonogenic survival. CONCLUSION: Irrespective of oxygen tension, FLASH-RT produces translocations and junction structures at levels and proportions that are indistinguishable from CONV-RT.

12.
J Natl Compr Canc Netw ; 21(9): 961-979, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37673108

RESUMEN

Mesothelioma is a rare cancer originating in mesothelial surfaces of the peritoneum, pleura, and other sites. These NCCN Clinical Practice Guidelines in Oncology (NCCN Guidelines) focus on peritoneal mesothelioma (PeM). The NCCN Guidelines for PeM provide recommendations for workup, diagnosis, and treatment of primary as well as previously treated PeM. The diagnosis of PeM may be delayed because PeM mimics other diseases and conditions and because the disease is so rare. The pathology section was recently updated to include new information about markers used to identify mesothelioma, which is difficult to diagnose. The term "malignant" is no longer used to classify mesotheliomas, because all mesotheliomas are now defined as malignant.


Asunto(s)
Mesotelioma Maligno , Mesotelioma , Humanos , Oncología Médica , Mesotelioma/diagnóstico , Mesotelioma/terapia , Peritoneo
13.
JAMA Oncol ; 9(11): 1525-1534, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37707820

RESUMEN

Importance: Stereotactic ablative radiotherapy (SABR) is used for treating lung tumors but can cause toxic effects, including life-threatening damage to central structures. Retrospective data suggested that small tumors up to 10 cm3 in volume can be well controlled with a biologically effective dose less than 100 Gy. Objective: To assess whether individualizing lung SABR dose and fractionation by tumor size, location, and histological characteristics may be associated with local tumor control. Design, Setting, and Participants: This nonrandomized controlled trial (the iSABR trial, so named for individualized SABR) was a phase 2 multicenter trial enrolling participants from November 15, 2011, to December 5, 2018, at academic medical centers in the US and Japan. Data were analyzed from December 9, 2020, to May 10, 2023. Patients were enrolled in 3 groups according to cancer type: initial diagnosis of non-small cell lung cancer (NSCLC) with an American Joint Committee on Cancer 7th edition T1-3N0M0 tumor (group 1), a T1-3N0M0 new primary NSCLC with a history of prior NSCLC or multiple NSCLCs (group 2), or lung metastases from NSCLC or another solid tumor (group 3). Intervention: Up to 4 tumors were treated with once-daily SABR. The dose ranged from 25 Gy in 1 fraction for peripheral tumors with a volume of 0 to 10 cm3 to 60 Gy in 8 fractions for central tumors with a volume greater than 30 cm3. Main outcome: Per-group freedom from local recurrence (same-lobe recurrence) at 1 year, with censoring at time of distant recurrence, death, or loss to follow-up. Results: In total, 217 unique patients (median [IQR] age, 72 [64-80] years; 129 [59%] male; 150 [69%] current or former smokers) were enrolled (some multiple times). There were 240 treatment courses: 79 in group 1, 82 in group 2, and 79 in group 3. A total of 285 tumors (211 [74%] peripheral and 74 [26%] central) were treated. The most common dose was 25 Gy in 1 fraction (158 tumors). The median (range) follow-up period was 33 (2-109) months, and the median overall survival was 59 (95% CI, 49-82) months. Freedom from local recurrence at 1 year was 97% (90% CI, 91%-99%) for group 1, 94% (90% CI, 87%-97%) for group 2, and 96% (90% CI, 89%-98%) for group 3. Freedom from local recurrence at 5 years ranged from 83% to 93% in the 3 groups. The proportion of patients with grade 3 to 5 toxic effects was low, at 5% (including a single patient [1%] with grade 5 toxic effects). Conclusions and Relevance: The results of this nonrandomized controlled trial suggest that individualized SABR (iSABR) used to treat lung tumors may allow minimization of treatment dose and is associated with excellent local control. Individualized dosing should be considered for use in future trials. Trial Registration: ClinicalTrials.gov Identifier: NCT01463423.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Radiocirugia , Humanos , Masculino , Anciano , Femenino , Neoplasias Pulmonares/patología , Carcinoma de Pulmón de Células no Pequeñas/patología , Estudios Retrospectivos , Resultado del Tratamiento , Radiocirugia/efectos adversos , Radiocirugia/métodos
14.
Health Phys ; 125(4): 281-288, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37459481

RESUMEN

ABSTRACT: A preclinical radiotherapy system producing FLASH dose rates with 12 MV bremsstrahlung x rays is being developed at Stanford University and SLAC National Accelerator Laboratory. Because of the high expected workload of 6,800 Gy w -1 at the isocenter, an efficient shielding methodology is needed to protect operators and the public while the preclinical system is operated in a radiation therapy vault designed for 6 MV x rays. In this study, an analysis is performed to assess the shielding of the local treatment head and radiation vault using the Monte Carlo code FLUKA and the empirical methodology given in the National Council on Radiation Protection and Measurements Report 151. Two different treatment head shielding designs were created to compare single-layer and multilayer shielding methodologies using high-Z and low-Z materials. The multilayered shielding methodology produced designs with a 17% reduction in neutron fluence leaking from the treatment head compared to the single layered design of the same size, resulting in a decreased effective dose to operators and the public. The conservative assumptions used in the empirical methods can lead to over-shielding when treatment heads use polyethylene or multilayered shielding. High-Z/Low-Z multilayered shielding optimized via Monte Carlo is shown to be effective in the case of treatment head shielding and provide more effective shielding design for external beam radiotherapy systems that use 12 MV bremsstrahlung photons. Modifications to empirical methods used in the assessment of MV radiotherapy systems may be warranted to capture the effects of polyethylene in treatment head shielding.


Asunto(s)
Fotones , Oncología por Radiación , Humanos , Rayos X , Fotones/uso terapéutico , Radiografía , Polietileno , Método de Montecarlo , Aceleradores de Partículas , Neutrones
15.
Radiother Oncol ; 186: 109767, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37385377

RESUMEN

Long-term potentiation (LTP) was used to gauge the impact of conventional and FLASH dose rates on synaptic transmission. Data collected from the hippocampus and medial prefrontal cortex confirmed significant inhibition of LTP after 10 fractions of 3 Gy (30 Gy total) conventional radiotherapy. Remarkably, 10x3Gy FLASH radiotherapy and unirradiated controls were identical and exhibited normal LTP.


Asunto(s)
Potenciación a Largo Plazo , Plasticidad Neuronal , Ratones , Animales , Plasticidad Neuronal/fisiología , Potenciación a Largo Plazo/fisiología , Hipocampo/fisiología , Transmisión Sináptica/fisiología
16.
Pract Radiat Oncol ; 13(5): e383-e388, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37150318

RESUMEN

We present the case of a woman with metastatic adenoid cystic carcinoma who received stereotactic ablative radiation therapy with a total dose of 50 Gy in 4 fractions to 2 lung metastases and developed symptomatic left phrenic nerve injury 2 years after radiation. The maximum dose to the approximate location of the phrenic nerve was 57.7 Gy, which corresponds to a biologically effective dose for late effects (using α/ß ratio = 3) of 335.14 Gy. Here, we discuss the case, planning considerations by radiation oncologists and medical physicists, and the multidisciplinary medical management of this patient.


Asunto(s)
Neoplasias Pulmonares , Radiocirugia , Parálisis Respiratoria , Femenino , Humanos , Nervio Frénico/patología , Parálisis Respiratoria/etiología , Neoplasias Pulmonares/patología , Radiocirugia/efectos adversos , Progresión de la Enfermedad
17.
bioRxiv ; 2023 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-37034651

RESUMEN

The molecular and cellular mechanisms driving the enhanced therapeutic ratio of ultra-high dose-rate radiotherapy (FLASH-RT) over slower conventional (CONV-RT) radiotherapy dose-rate remain to be elucidated. However, attenuated DNA damage and transient oxygen depletion are among several proposed models. Here, we tested whether FLASH-RT under physioxic (4% O 2 ) and hypoxic conditions (≤2% O 2 ) reduces genome-wide translocations relative to CONV-RT and whether any differences identified revert under normoxic (21% O 2 ) conditions. We employed high-throughput rejoin and genome-wide translocation sequencing ( HTGTS-JoinT-seq ), using S. aureus and S. pyogenes Cas9 "bait" DNA double strand breaks (DSBs), to measure differences in bait-proximal repair and their genome-wide translocations to "prey" DSBs generated by electron beam CONV-RT (0.08-0.13Gy/s) and FLASH-RT (1×10 2 -5×10 6 Gy/s), under varying ionizing radiation (IR) doses and oxygen tensions. Normoxic and physioxic irradiation of HEK293T cells increased translocations at the cost of decreasing bait-proximal repair but were indistinguishable between CONV-RT and FLASH-RT. Although no apparent increase in chromosome translocations was observed with hypoxia-induced apoptosis, the combined decrease in oxygen tension with IR dose-rate modulation did not reveal significant differences in the level of translocations nor in their junction structures. Thus, Irrespective of oxygen tension, FLASH-RT produces translocations and junction structures at levels and proportions that are indistinguishable from CONV-RT.

18.
Front Oncol ; 13: 1139940, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37035171

RESUMEN

Objective: The 2-year incidence of brain metastases (BrMs) in stage III non-small lung cell cancer (NSCLC) has been estimated to be around 30%. However, recent clinical trials have demonstrated considerably lower BrMs rates in this patient population. In this study, we aimed to review the real-world incidence, surveillance, and treatment patterns of BrMs in stage III NSCLC. Materials and methods: Using a retrospective single-center study design, we identified patients with stage III NSCLC who received radiation with curative intent over a 10-year period. Outcome variables included BrMs incidence, overall survival (OS), and survival from date of BrMs. Additionally, we assessed patterns of BrMs surveillance in stage III NSCLC and treatment. Results: We identified a total of 279 stage III NSCLC patients, of which 160 with adequate records were included in the final analyses [adenocarcinoma (n = 96), squamous cell carcinoma (n = 53), other histology subtype (n = 11)]. The median OS for the entire cohort was 41 months (95% CI, 28-53), while the median time from BrMs to death was 19 months (95% CI, 9-21). Twenty-three patients (14.4%) received planned surveillance brain MRIs at 6, 12, and 24 months after completion of treatment. The remaining 137 patients (85.6%) received brain MRIs at systemic recurrence (restaging) or when neurologically symptomatic. A total of 37 patients (23%) developed BrMs, with a 2-year cumulative BrMs incidence of 17% (95% CI, 11-23). A higher incidence of BrMs was identified in patients with adenocarcinoma relative to those with squamous cell carcinoma (p < 0.01). Similarly, a higher 2-year BrMs incidence was observed in patients who received planned surveillance brain MRI relative to those who did not, although statistical significance was not reached. Stereotactic radiosurgery (SRS) treated 29 of BrMs patients (78.4%) and was preferred over WBRT, which treated only 3 patients (8.1%). Conclusions: At our center, BrMs incidence in stage III NSCLC patients was lower than historically reported but notably higher than the incidence described in recent clinical trials. Routine BrMs surveillance potentially allows earlier detection of asymptomatic BrMs. However, asymptomatic BrMs were mostly detected on restaging MRI at the time of recurrence.

19.
Int J Radiat Oncol Biol Phys ; 117(2): 482-492, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37105403

RESUMEN

PURPOSE: Ultrahigh-dose-rate (UHDR) radiation therapy (RT) has produced the FLASH effect in preclinical models: reduced toxicity with comparable tumor control compared with conventional-dose-rate RT. Early clinical trials focused on UHDR RT feasibility using specialized devices. We explore the technical feasibility of practical electron UHDR RT on a standard clinical linear accelerator (LINAC). METHODS AND MATERIALS: We tuned the program board of a decommissioned electron energy for UHDR electron delivery on a clinical LINAC without hardware modification. Pulse delivery was controlled using the respiratory gating interface. A short source-to-surface distance (SSD) electron setup with a standard scattering foil was configured and tested on an anthropomorphic phantom using circular blocks with 3- to 20-cm field sizes. Dosimetry was evaluated using radiochromic film and an ion chamber profiler. RESULTS: UHDR open-field mean dose rates at 100, 80, 70, and 59 cm SSD were 36.82, 59.52, 82.01, and 112.83 Gy/s, respectively. At 80 cm SSD, mean dose rate was ∼60 Gy/s for all collimated field sizes, with an R80 depth of 6.1 cm corresponding to an energy of 17.5 MeV. Heterogeneity was <5.0% with asymmetry of 2.2% to 6.2%. The short SSD setup was feasible under realistic treatment conditions simulating broad clinical indications on an anthropomorphic phantom. CONCLUSIONS: Short SSD and tuning for high electron beam current on a standard clinical LINAC can deliver flat, homogenous UHDR electrons over a broad, clinically relevant range of field sizes and depths with practical working distances in a configuration easily reversible to standard clinical use.


Asunto(s)
Electrones , Neoplasias , Humanos , Radiometría/métodos , Aceleradores de Partículas , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica
20.
J Natl Compr Canc Netw ; 21(4): 340-350, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-37015337

RESUMEN

The NCCN Guidelines for Non-Small Cell Lung Cancer (NSCLC) provide recommendations for management of disease in patients with NSCLC. These NCCN Guidelines Insights focus on neoadjuvant and adjuvant (also known as perioperative) systemic therapy options for eligible patients with resectable NSCLC.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/terapia , Terapia Neoadyuvante
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...